FleetView IQ
EV Fleet Intelligence Platform
← Battery APM
42health

SHU-03

At Risk
Shuttle · NMC · 101 kWh
Harbor Depot · commissioned 2024-08-28 · 372,788 km
State of health
86.1%
Remaining life
1.2y
92% conf
Fade rate
0.42%/mo
Full cycles
805
Resistance rise
+31%
Proj. end-of-life
2027-09-24
Degradation trajectory
SoH history + linear projection to 80.0% end-of-life
observedprojectedEoL
77%82%87%JanFebMarAprMayJunJulEnd-of-life 80%proj. 2027-09-24
APM Agent diagnosis
Idle.
Peak temp37°C
Depth of discharge68%
Internal resistance1.31×
Cycles / day1.07EFC
Maintenance triggers
2 active
Recent thermal excursionhigh
Thermal event 9d ago (peak 65°C). Inspect cooling loop and cell balance.
9d ago
Internal resistance climbingmedium
DC internal resistance up 31% vs beginning-of-life — power fade and heating risk.
+31% R
Charge–discharge optimization
engine-generated actions, highest leverage first
Charging~+105d life
Cap DC fast-charge share below 25% (currently 50%)
High-C-rate sessions drive lithium plating and heat. Shift toward overnight AC charging where the duty cycle allows.
Charging~+40d life
Hold depot charge ceiling at 80% SoC unless full range is scheduled
Time spent at high state-of-charge is the dominant calendar-aging driver. Charge-to-need before departure.
Thermal~+140d life
Enable active pre-conditioning and cooling before fast charge; inspect coolant loop
Elevated pack temperatures and thermal excursions were logged. Keeping cells under 35°C during charge cuts fade sharply.
Balancing~+25d life
Schedule cell-balancing and a full capacity test at next service
Rising internal resistance / non-linear fade suggests cell divergence. Balancing recovers usable capacity and flags weak modules.
Thermal event log
14 total · 6 months
DateWhenTriggerPeak temp
2026-07-139d agoHigh load63.4°C
2026-06-2824d agoFast charge58.0°C
2026-05-162mo agoHigh load58.9°C
2026-05-132mo agoHigh load64.1°C
2026-04-303mo agoHigh load63.5°C
2026-04-293mo agoFast charge52.0°C