FleetView IQ
EV Fleet Intelligence Platform
← Battery APM
17health

SHU-04

Critical↗ knee detected
Shuttle · LFP · 119 kWh
North Yard · commissioned 2022-08-03 · 823,869 km
State of health
83.3%
Remaining life
6mo
77% conf
Fade rate
0.53%/mo
Full cycles
1,971
Resistance rise
+30%
Proj. end-of-life
2027-01-21
Degradation trajectory
SoH history + linear projection to 80.0% end-of-life
observedprojectedEoL
77%82%JanFebMarAprMayJunJulEnd-of-life 80%proj. 2027-01-21
APM Agent diagnosis
Idle.
Peak temp28°C
Depth of discharge52%
Internal resistance1.30×
Cycles / day1.38EFC
Maintenance triggers
4 active
Degradation knee detectedhigh
Recent fade is 2.6× the early-life rate — non-linear capacity loss underway.
2.6× early rate
Remaining useful life under 12 monthsmedium
Projected end-of-life in ~183 days. Begin procurement planning.
RUL 183d
Repeated thermal eventsmedium
7 thermal excursions in the trailing 6 months.
7 events
Internal resistance climbingmedium
DC internal resistance up 30% vs beginning-of-life — power fade and heating risk.
+30% R
Charge–discharge optimization
engine-generated actions, highest leverage first
Charging~+127d life
Cap DC fast-charge share below 25% (currently 69%)
High-C-rate sessions drive lithium plating and heat. Shift toward overnight AC charging where the duty cycle allows.
Charging~+40d life
Hold depot charge ceiling at 80% SoC unless full range is scheduled
Time spent at high state-of-charge is the dominant calendar-aging driver. Charge-to-need before departure.
Thermal~+110d life
Enable active pre-conditioning and cooling before fast charge; inspect coolant loop
Elevated pack temperatures and thermal excursions were logged. Keeping cells under 35°C during charge cuts fade sharply.
Balancing~+25d life
Schedule cell-balancing and a full capacity test at next service
Rising internal resistance / non-linear fade suggests cell divergence. Balancing recovers usable capacity and flags weak modules.
Inspection
Prioritise teardown inspection and plan replacement or second-life redeployment
Asset is at or near end-of-first-life. Grid-storage second life can recover residual value below 80% SoH.
Thermal event log
7 total · 6 months
DateWhenTriggerPeak temp
2026-06-161mo agoFast charge56.9°C
2026-05-282mo agoFast charge52.1°C
2026-04-293mo agoFast charge61.0°C
2026-04-283mo agoFast charge58.3°C
2026-03-174mo agoFast charge65.7°C
2026-02-046mo agoFast charge64.7°C